●商品名:IBM #2498-24E×2台セット!(#F4-650)です。BROCADE 300 OEM。 ●写真の通りの商品です。 ●Login:admin/Password:password。SFP [8GB]×8個を実装しています。 ●機器起動時は次の状態です。 U-Boot 1.1.3 (Aug 22 2014 - 10:53:59)
CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Tomahawk
I2C: ready
DRAM: Initializing DDRSDRAM
DDR Init: speed = 132000002
DQS calibration - Window detected:
max_passing_cases = 56
wr_dqs_shift = 91
dll_dqs_delay_X = 31
dll_dqs_delay_X window = 4 - 59
DDR0_09=0x00011d5b
DDR0_22=0x00267b0b
DDR0_17=0x1f005e00
DDR0_18=0x1f1f1f1f
DDR0_19=0x1f1f1f1f
ECC Enabling DONE
512 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 1fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Tomahawk CFI Flash Driver Initialized
4 MB
ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
00 07 1657 0011 0280 18
In: serial
Out: serial
Err: serial
Net:
Checking system RAM - press any key to stop test
Checking memory address: 00100000
System RAM test using Default POST RAM Test succeeded.
set_bootstatus: BS_LOAD_OS, platform_idx = 1
Type run flash_nfs to mount root filesystem over NFS
Hit ESC to stop autoboot: 0
Map file at LBA sector 0x177e60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211398 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x1FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1f9df000, end 1fae6587 ... OK
initrd_start = 1f9df000, initrd_end = 1fae6587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
sys_chip_init: class 0 max 24 Done
ethsw_ha_enabled = 1
uptime: 4293888961; sup_qid: 0
.
Fabric OS (switch)
switch console login: 2023/11/13-19:01:14, [HAM-1004], 5164, CHASSIS,
INFO, IBM_2498_24E, Processor rebooted - Reboot.
2023/11/13-19:01:30, [FV-1001], 5165, CHASSIS, INFO, switch,
Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2023/11/13-19:01:39, [FV-1002], 5166, FID 128, INFO, switch,
Flow Vision Config Replay Completed Successfully.
Nov 13 19:01:41 All service instances on Active
POST1: Started running Mon Nov 13 19:01:44 JST 2023
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Nov 13 19:02:00 JST 2023 took (0:0:16)
POST2: Started running Mon Nov 13 19:02:01 JST 2023
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Running diagshow
POST2: Script PASSED with exit status of 0 Mon Nov 13 19:02:09 JST 2023 took (0:0:8)
2023/11/13-19:02:11, [BL-1000], 5167, CHASSIS, INFO, IBM_2498_24E,
Initializing ports...
2023/11/13-19:02:11, [BL-1001], 5168, CHASSIS, INFO, IBM_2498_24E,
Port initialization completed.
Fabric OS (switch)
switch console login: admin
Password:
switch:admin>
switch:admin> switchshow
switchName: switch
switchType: 71.2
switchState: Online
switchMode: Native
switchRole: Principal
switchDomain: 1
switchId: fffc01
switchWwn: 10:00:50:eb:1a:16:**:**
zoning: OFF
switchBeacon: OFF
Index Port Address Media Speed State Proto
==================================================
0 0 010000 id N8 No_Light FC
1 1 010100 id N8 No_Light FC
2 2 010200 id N8 No_Light FC
3 3 010300 id N8 No_Light FC
4 4 010400 id N8 No_Light FC
5 5 010500 id N8 No_Light FC
6 6 010600 id N8 No_Light FC
7 7 010700 id N8 No_Light FC
8 8 010800 -- N8 No_Module FC (No POD License) Disabled
9 9 010900 -- N8 No_Module FC (No POD License) Disabled
10 10 010a00 -- N8 No_Module FC (No POD License) Disabled
11 11 010b00 -- N8 No_Module FC (No POD License) Disabled
12 12 010c00 -- N8 No_Module FC (No POD License) Disabled
13 13 010d00 -- N8 No_Module FC (No POD License) Disabled
14 14 010e00 -- N8 No_Module FC (No POD License) Disabled
15 15 010f00 -- N8 No_Module FC (No POD License) Disabled
16 16 011000 -- N8 No_Module FC (No POD License) Disabled
17 17 011100 -- N8 No_Module FC (No POD License) Disabled
18 18 011200 -- N8 No_Module FC (No POD License) Disabled
19 19 011300 -- N8 No_Module FC (No POD License) Disabled
20 20 011400 -- N8 No_Module FC (No POD License) Disabled
21 21 011500 -- N8 No_Module FC (No POD License) Disabled
22 22 011600 -- N8 No_Module FC (No POD License) Disabled
23 23 011700 -- N8 No_Module FC (No POD License) Disabled
switch:admin> licenseshow
GgmKAYSXBrrZYaGfHSARC7XD4tFrXmFgBJTtB:
8 Gig FC license
switch:admin> version
Kernel: 2.6.14.2
Fabric OS: v7.2.1c
Made on: Thu Aug 28 22:57:47 2014
Flash: Wed Oct 22 14:51:27 2014
BootProm: 1.0.11
switch:admin> sfpshow
Port 0: id (sw) Vendor: BROCADE Serial No: UAF414230001*** Speed: 2,4,8_Gbps
Port 1: id (sw) Vendor: BROCADE Serial No: UAF414230001*** Speed: 2,4,8_Gbps
Port 2: id (sw) Vendor: BROCADE Serial No: UAF414230001*** Speed: 2,4,8_Gbps
Port 3: id (sw) Vendor: BROCADE Serial No: UAF414230001*** Speed: 2,4,8_Gbps
Port 4: id (sw) Vendor: BROCADE Serial No: UAF414230001*** Speed: 2,4,8_Gbps
Port 5: id (sw) Vendor: BROCADE Serial No: UAF414230001*** Speed: 2,4,8_Gbps
Port 6: id (sw) Vendor: BROCADE Serial No: UAF414230001*** Speed: 2,4,8_Gbps
Port 7: id (sw) Vendor: BROCADE Serial No: UAF414230001*** Speed: 2,4,8_Gbps
Port 8: --
Port 9: --
Port 10: --
Port 11: --
Port 12: --
Port 13: --
Port 14: --
Port 15: --
Port 16: --
Port 17: --
Port 18: --
Port 19: --
Port 20: --
Port 21: --
Port 22: --
Port 23: --
switch:admin> diagshow
Diagnostics Status: Mon Nov 13 19:03:06 2023
Slot: 0 UPORTS
Port BPort Diag Active Speed FrTX FrRX LLI Errs Loopback
0/0 23 OK DN 8G Auto -- -- --
0/1 21 OK DN 8G Auto -- -- --
0/2 19 OK DN 8G Auto -- -- --
0/3 17 OK DN 8G Auto -- -- --
0/4 22 OK DN 8G Auto -- -- --
0/5 20 OK DN 8G Auto -- -- --
0/6 18 OK DN 8G Auto -- -- --
0/7 16 OK DN 8G Auto -- -- --
0/8 15 OK DN 8G Auto -- -- --
0/9 13 OK DN 8G Auto -- -- --
0/10 11 OK DN 8G Auto -- -- --
0/11 9 OK DN 8G Auto -- -- --
0/12 14 OK DN 8G Auto -- -- --
0/13 12 OK DN 8G Auto -- -- --
0/14 10 OK DN 8G Auto -- -- --
0/15 8 OK DN 8G Auto -- -- --
0/16 7 OK DN 8G Auto -- -- --
0/17 5 OK DN 8G Auto -- -- --
0/18 3 OK DN 8G Auto -- -- --
0/19 1 OK DN 8G Auto -- -- --
0/20 6 OK DN 8G Auto -- -- --
0/21 4 OK DN 8G Auto -- -- --
0/22 2 OK DN 8G Auto -- -- --
0/23 0 OK DN 8G Auto -- -- --
Total Diag Frames Tx: 120
Total Diag Frames Rx: 120
switch:admin> chassisshow
POWER SUPPLY Unit: 1
Time Awake: 0 days
FAN Unit: 1
Time Awake: 0 days
FAN Unit: 2
Time Awake: 0 days
FAN Unit: 3
Time Awake: 0 days
CHASSIS/WWN Unit: 1
Header Version: 2
Factory Part Num: 40-1000165-14
Factory Serial Num: ALJ2526****
Manufacture: Day: 26 Month: 4 Year: 2014
Update: Day: 31 Month: 10 Year: 2023
Time Alive: 3228 days
Time Awake: 0 days
ID: IBM0000CA
Part Num: 002498000024E
Serial Num: 103****
switch:admin> chassisname
IBM_2498_24E
switch:admin> ●使用されていた商品ですが、全機能を検証する環境が無い為、それ以上の動作は未確認です。 ●「電源が入らない」以外は、現状・ノークレーム扱いでの出品とさせて頂きます。 ●出品は、写真の商品×2台のみ、です。電源ケーブル等、付属品は一切ありません。 ●写真をご参照の上、ご入札のほど、宜しくお願いします。 ●送料は下記の「120サイズ」(2台1セットあたり)となります。 ●運輸業者は当方で決めさせていただきます。 ●上記の発送サイズは2台1セットの場合です。複数同時発送の場合の送料はこちらからご連絡いたします。 ●中古のダンボールを使用する事より実際の発送サイズが異なる場合がございます。ご了承下さいませ。 ●東京都江戸川区西一之江の倉庫にてのお渡しも可能です。 ●その場合は、無梱包お渡しとなります。 ●営業時間は月曜日~金曜日、AM10:00~PM18:00となります。 ●第1.3.5土曜日のみ、11:00~15:00に限り、営業致します。 ●第2.4土曜日・日曜日・祝日は休みになります。 ●こちらからのご連絡は平日昼間のみとなります。 ●また、お取引後の評価ですが不要のお客様が多い為にこちらからは入れておりま せん。 ●評価が必要なお客様は取引メッセージにてのご連絡をお願い致します。
|